NG-310 HEATERS


Depending on the power of the installed heaters and on the amount of air flowing through, the air temperature increses by 2 to 8oC. This small increase in the temperature results in a significant decrease in the air relative humidity. Air with low relative humidity can absorb water from wet grain stored in silos. The standard heater is configured only for work with the PPZt-7.5-WNT ventilator produced by BIN. Standard heaters can work in silos where air inlet has a diameter of f310mm. In other cases it is necessary to adjust the heater to a given air inlet installed in silo.

Basic technical data for the NG-310 heater.


NG-310-4.5 NG-310-9.0
Rated power 4.5kW 9.0kW
Power supply voltage 3x400V/50Hz 3x400V/50Hz
Type of heating elements pipe 1.5kW/400V pipe 1.5kW/400V
Number of heating elements 3 6
Inlet /outlet diameter f310 /f310 f310 /f310
Minimum required air circulation 700 m3/h 0.2m3/s 1400 m3/h 0.4m3/s
Maximum permissible temperature increase 20oC 20oC
Overall dimensions D x S x H 450/500/420 450/500/420
Weight 11kg 12.5kg
Designed for silos (recommended) BIN10 - BIN100W BIN 200, BIN200W